Operating temperature up to +150°C (+302°F)
Provides electromagnetic shielding
Self-wrapping design
Integrated drain wire for proper grounding
FUNCTION:
• Instrument panel harnesses
• Engine compartment harnesses
• Battery cables
• Interior harnesses
There are no installation guides available at this time. Please contact your sales representative or distribution team for further support.
For optimal viewing experience on a mobile device, rotate to a landscape orientation.
Property | Test Method | Result |
|---|---|---|
Temperature Rating | 240 hours at +175°C (+150°C rating) | Pass +150°C (+302°F) |
Low Temperature Flexibility | BH100-016A | Pass -40°C (-40°F) |
Flammability | SAE J369 | Self-extinguishing |
Fluid Resistance | BH100-003B | Pass |
Salt Spray Endurance | ASTM G85 | Pass - No corrosion |
Shielding Effectiveness | IEC 62153-4-3 | See graph below |