ROUNDIT® V0 EMI

Operating temperature -50ºC to +200ºC (-58ºF to +392ºF)

Self-wrapping design

Fast and easy installation for local EMI protection

Stable construction

Ideal for reworking components without disconnecting them

EN45545-2

NFPA 130
     – ASTM E-162
     – ASTM E-662

BSS 7239

SMP 800-C

Zero halogen

UL 94 V0 Raw Material

Cu/Ni metal (ASTM B-355)

Good level of EMI Shielding
     – Ro max = 6 mΩ
     – Lt = 1.2 nH/m

FUNCTION:

Stacks Image 6847
Open all Close all
  • Product Description

    ROUNDIT® V0 EMI is a wrap-around sleeving designed for high performance EMI shielding of wire and cable bundles. ROUNDIT V0 EMI is manufactured from UL 94 V0 rated PPS monofilaments and nickel plated copper wires class 4 according to ASTM B-355.

    The self-wrapping feature of ROUNDIT V0 EMI allows for quick and easy installation and removal of the product for assembly and maintenance.

    The design offers innovative solutions to the protection of breakout areas and also provides ease of removal when inspection or maintenance of cables is necessary.

    The stable construction guarantees the same level of EMI shielding regardless of the diameter on which it is installed within the recommended application range.

    As an additional benefit, ROUNDIT V0 EMI enables users to stock a limited range of sizes to cover a wide range of cable and wire diameters.

    ROUNDIT V0 EMI has many applications in the railway, marine and electronics industries.

  • Datasheet Downloads
  • Sizes / Availability

    Product Specifications

    Commercial Part Number
    Nominal
    Size*
    mm
    Recommended Application Range mm (in)
    Min Ø
    Max Ø
    Sleeve
    Cross Section
    mm
    2
    Max Mass
    g/m
    Standard Packaging
    m (ft)
    ROUNDIT V0 EMI 8
    8
    5 (3/16")
    8 (5/16")
    3.5
    40
    250 (820')
    ROUNDIT V0 EMI 13
    13
    8 (5/16")
    13 (1/2")
    4.8
    55
    175 (574')
    ROUNDIT V0 EMI 19
    19
    13 (1/2")
    19 (3/4")
    5.9
    66
    125 (410')
    ROUNDIT V0 EMI 25
    25
    19 (3/4")
    25 (1")
    6.9
    80
    75 (246')
    ROUNDIT V0 EMI 32
    32
    25 (1")
    32 (1-1/4")
    8.9
    105
    50 (164')
    ROUNDIT V0 EMI 38
    38
    32 (1-1/4")
    38 (1-1/2")
    10.6
    120
    35 (114')
    ROUNDIT V0 EMI 45**
    45
    38 (1-1/2")
    45 (1-3/4")
    11.9
    140
    35 (114')

    *Nominal size is determined by wrapping the product around a mandrel of a given size to obtain 90 degrees of overlap (average value).

    ** Size 45 has 80 degrees of overlap (average value).

    Part Numbering System

    Example



    Product Name
    Size
    Color
    Quantity
    ROUNDIT V0 EMI
    13
    8 (light gray)
    175m
  • Installation Tools

    As an added benefit, the patented ROUNDIT® Tool will help improve installation time and is designed to install ROUNDIT® products on cable and wire configurations.

  • Product Testing

    Performance Data - ROUNDIT® V0 EMI

    For optimal viewing experience on a mobile device, rotate to a landscape orientation.

    Property
    Test Method
    Result
    PHYSICAL
    Operating Temperature Range
    -50ºC to +200ºC (-58°F to +392°F)
    Heat aging
    EN6059-302 (168 hours)
    +200°C (+392°F)
    Fire / smoke / toxicity
    UL 94
    BS6853

    DIN 5510 §2 & 54837
    EN 45545-2
    Raw material classified V0
    Zero halogen
    Toxicity R< 1.0
    S4, SR2, ST2
    R22 HL3 R23 HL3
    Nickel plated copper
    ASTM B-355
    Nickel plated copper Class 4
    CHEMICAL
    Fluid Resistance
       – Hydraulic Fluids NATO.0.156
    EN 6059-303
    Immersion for 24hrs at +70°C
    D47 1924
    No visible degradation after being exposed
    Salt spray resistance
    EN 2591-307 – 96 hours
    Pass
    EMI PERFORMANCE
    Resistance Measurement

    EN 3475-301
    R0 max all sizes = 6 mΩ

    Transfer Impedance

    IEC 62153-4-3 Triaxial method on straight installation
    Lt = 1.2 nH

    All numeric performance data shows average or typical values. Please consult your sales representative for product drawings, test reports and OEM approvals.