Operating temperature -50ºC to +200ºC (-58ºF to +392ºF)
Self-wrapping design
Fast and easy installation for local EMI protection
Stable construction
Ideal for reworking components without disconnecting them
Zero halogen
EN45545-2
NFPA 130
– ASTM E-162
– ASTM E-662
BSS 7239
SMP 800-C
UL 94 V0 Raw Material
Cu/Sn metal (EN13602)
Good level of EMI Shielding
– Ro max = 6 mΩ
– Lt = 1.2 nH/m
FUNCTION:
ROUNDIT® V0 EMI Cu/Sn is a wrap-around sleeving designed for high performance EMI shielding of wire and cable bundles. ROUNDIT V0 EMI Cu/Sn is manufactured from UL 94 V0 rated PPS monofilaments and tin plated copper wires according to EN13602.
The self-wrapping feature of ROUNDIT V0 EMI Cu/Sn allows for quick and easy installation and removal of the product for assembly and maintenance.
The design offers innovative solutions to the protection of breakout areas and also provides ease of removal when inspection or maintenance of cables is necessary.
The stable construction guarantees the same level of EMI shielding regardless of the diameter on which it is installed within the recommended application range.
As an additional benefit, ROUNDIT V0 EMI Cu/Sn enables users to stock a limited range of sizes to cover a wide range of cable and wire diameters.
ROUNDIT V0 EMI Cu/Sn has many applications in the railway, marine and electronics industries.
Commercial Part Number | Nominal Size* mm | Recommended Application Range mm (in) Min Ø Max Ø | Sleeve Cross Section mm2 | Max Mass g/m | Standard Packaging m (ft) |
|---|---|---|---|---|---|
ROUNDIT V0 EMI CuSn 8 | 8 |
5 (3/16") 8 (5/16") | 3.5 | 41 (0.028) | 250 (820') |
ROUNDIT V0 EMI CuSn 13 | 13 |
8 (5/16") 13 (1/2") | 4.8 | 55 (0.037) | 175 (574') |
ROUNDIT V0 EMI CuSn 19 | 19 |
13 (1/2") 19 (3/4") | 5.9 | 67 (0.045) | 125 (410') |
ROUNDIT V0 EMI CuSn 25 | 25 |
19 (3/4") 25 (1") | 6.9 | 80 (0.054) | 75 (246') |
ROUNDIT V0 EMI CuSn 32 | 32 |
25 (1") 32 (1-1/4") | 8.9 | 105 (0.071) | 50 (164') |
ROUNDIT V0 EMI CuSn 38 | 38 |
32 (1-1/4") 38 (1-1/2") | 10.6 | 120 (0.081) | 35 (114') |
ROUNDIT V0 EMI CuSn 45** | 45 |
38 (1-1/2") 45 (1-3/4") | 11.9 | 140 (0.094) | 35 (114') |
*Nominal size is determined by wrapping the product around a mandrel of a given size to obtain 90 degrees of overlap (average value).
** Size 45 has 80 degrees of overlap (average value).
Example
Product Name | Size | Color | Quantity |
|---|---|---|---|
ROUNDIT V0 EMI CuSn | 13 | 8 (light gray) | 175m |
As an added benefit, the patented ROUNDIT® Tool will help improve installation time and is designed to install ROUNDIT® products on cable and wire configurations.
For optimal viewing experience on a mobile device, rotate to a landscape orientation.
Property | Test Method | Result |
|---|---|---|
PHYSICAL | ||
Operating Temperature Range | -40ºC to +125ºC (-40°F to +257°F) |
|
Fire / smoke / toxicity | UL 94 DIN 5510 §2 & 54837 EN 45545-2 | Raw material classified V0 S4, SR2, ST2 R22 HL3 R23 HL3 |
CHEMICAL | ||
Fluid Resistance – Hydraulic Fluids NATO.0.156 | EN 6059-303 Immersion for 24hrs at +70°C D47 1924 | No visible degradation after being exposed |
Salt spray resistance | EN 2591-307 – 96 hours | Pass |
EMI PERFORMANCE | ||
Resistance Measurement EN 3475-301 R0 max all sizes = 6 mΩ Transfer Impedance IEC 62153-4-3 Triaxial method on straight installation Lt = 1.2 nH |
|
|
All numeric performance data shows average or typical values. Please consult your sales representative for product drawings, test reports and OEM approvals.